The RS-422/485 port of the PES-2407 is a terminal block. It has six terminals and a 5mm pitch.
Number | Name | Description | Level | I/O | Wiring |
---|---|---|---|---|---|
1 | TX+ | Transmit Data+ | RS-422 | Out | Required |
2 | TX- | Transmit Data- | RS-422 | Out | Required |
3 | GND | Ground | Ground | - | Required |
4 | RX+ | Receive Data+ | RS-422 | In | Required |
5 | RX- | Receive Data- | RS-422 | In | Required |
6 | GND | Ground | Ground | - | Required |
Number | Name | Description | Level | I/O | Wiring |
---|---|---|---|---|---|
1 | TRX+ | Transmit / Receive Data+ | RS-485 | In/Out | Required |
2 | TRX- | Transmit / Receive Data- | RS-485 | In/Out | Required |
3 | GND | Ground | Ground | - | Required |
6 | GND | Ground | Ground | - | Required |
A slave ID is used when PHPoC board identifies each smart expansion board. So, each smart expansion board, which is connected to a PHPoC board, should have a unique slave ID. The slave ID can be set one of the numbers from 1 to 14 by 4 DIP switches as follows:
PES-2407 has 7 LEDs. Two of these are STS LEDs that indicate the status of the board. The one, on the top of the board, is connected to 3.3V and the other one, on the bottom of the board is connected to 5V. The rest five of them are LEDs indicating various states of serial communication. The operation and meanings of each LED are as follows:
Name | Quantity | Type | Color | Operation |
---|---|---|---|---|
STS | 2 | SMD | Red | ID setting is normal > Repeated on / off every 1 second ID setting is incorrect > Fast flashing |
TX | 2 | DIP, SMD | Green | Blinks when sending data to the serial port |
RX | 2 | DIP, SMD | Yellow | Blinks when receiving data to the serial port |
TXDE | 1 | SMD | Green | enabling TxDE control > blinks when it sends data disabling TxDE control > always on |