The command to set RS-422/485 communication parameters is uart.
"set uart (parameter)"
Specify a string of the following form in parameter.
"(baudrate)[parity[data bit[stop bit[flow control]]]]"
※ (): mandatory, []: optional
Paramater | Values | Description | Default Value |
---|---|---|---|
baudrate | 1200 ~ 115200 | baudrate(bps) | 115200 |
parity | N, E, O, M or S | parity bit (N: None, E: Even, O: Odd, M: Mark, S: Space) |
N |
data bit | 8 or 7 | data bit | 8 |
stop bit | 1 or 2 | stop bit | 1 |
flow control | T or N | T: Enable TxDE control - On when send data N: Diable TxDE control - always On |
T |
※ Note : It is recommended to always use the default value of T for the flow control setting.
<?php
include "/lib/sd_spc.php";
$sid = 14;
spc_reset();
spc_sync_baud(115200);
spc_request_dev($sid, "set uart 115200");
echo spc_request_dev($sid, "get uart"), "\r\n"; // output: 115200N81T
spc_request_dev($sid, "set uart 115200N81T");
echo spc_request_dev($sid, "get uart"), "\r\n"; // output: 115200N81T
spc_request_dev($sid, "set uart 9600E72T");
echo spc_request_dev($sid, "get uart"); // output: 9600E72T
?>